<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-10 05-06-06
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 60 dBuV SANDELS
Pilot RDS Phase Difference
6.1 kHz 5.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 74 kHz 9291 14,5625
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,4 dBr 5,68 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 74 kHz MIN: 16 kHz % above 76 kHz: 14,5625 Acquired: 2024/12/10 5.05.02 Total samples: 9291 Equivalent time: 0:07:44 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,3 dBr MIN: 4,4 dBr AVE: 5,68 dBr % above 12,2 dBr: 0,0 Last value: 6,1 dBr (2024/12/10 5.05.02) 04.52 04.54 04.56 04.58 05.00 05.02 05.04 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]